mobil:assemblies:structures:hub_garage
Table of Contents
Hub (garage)
assembly structure shelter
An enclosed 2×1 hub from the 1,33 m module — a lockable garage volume with floor, walls, roof and a door. Storage on site without a building.
- Type: Structure
- Status: In use
- Primary function: storage / garage hub
1. At a glance
| Specification | Value |
|---|---|
| Footprint | 1,33 x 2,66 m |
| Height | 1,33 m |
| Volume | 4,70 m3 |
| Total weight | 34,5 kg |
| Assembly time | . (to define) |
| People needed | . (to define) |
| Tools | Hammer (optional, for pins) |
2. 3D model & steps
If the model doesn't load, open it in a new tab.
3. Parts (bill of materials)
Everything you need to build one garage hub. All tubes diameter 50 x 2 mm wall. Click a part for specs and handling.
| Part | Qty | Spec |
|---|---|---|
| Straight tube | 20 | 1329,4 mm |
| T-connector | 24 | 2 per connector node |
| X-connector | 12 | 1 per connector node |
| Locking pin | . | 1 per tube-connector joint |
| Panel (floor/wall/roof) | 10 | 1329,4 x 1329,4 mm |
| Panel door | . | (to define) |
| Corner profile | . | (to define - floor / flat / right-angle mix) |
| Corner hinge | . | (to define - for door) |
- Connector nodes: 12 (each = 2x T + 1x X)
- No diagonals - the garage is a panelled box, braced by its panels and corner profiles.
- Tubes total: 20 - tube length: 26,59 m
- Tube weight: 21,6 kg - connector weight: 12,8 kg - total: 34,5 kg
Source: MoBil builder (tubes, connectors, panel count). Door, corner-profile and hinge counts to confirm - the builder does not quantify hub elements.
4. Assembly
A panelled box on a 2×1 footprint. Each node = the connector assembly (2x T + 1x X), joined by tubes.
- Lay out the base. Set connectors in a 2×1 rectangle.
- Connect with straight tubes.
- Add the verticals. One straight tube into each node, pointing up.
- Close the top surface with straight tubes.
- Add the floor panels with aluminium corners.
- Add side and roof panels, joined with aluminium corner profiles. Leave the door opening open.
- Hang the door on the aluminium door hinge.
Each step maps to a stage in the viewer above.
5. Safety & correct use
Build safety
- Pinch points at every connector and panel edge - keep fingers clear when seating joints and profiles.
- Don't hammer pins with the frame unsupported; seat the joint by hand first.
- Panels are rigid and have weight - handle with two hands.
Use & load limits
- Max roof load: . kg (to define / test)
- Do not climb on the roof unless rated and ballasted.
- Wind: above . km/h, the closed box is a sail - ballast or take down. (define - enclosed volume)
- Lock the door; don't store hazardous or heavy loose loads that can shift.
Ballast / anchoring
- Footprint anchoring with water weights at the corners - the enclosed volume catches wind.
- Ropes to fixed points where available.
- Minimum ballast: . kg per corner (define per configuration).
6. Takedown & storage
- Empty the hub and remove ballast first.
- Lift off the door, then roof and side panels.
- Remove corner profiles and floor panels.
- Pull top pins, lift off the top surface, pull verticals.
- Break the base. Nodes can stay assembled for next time, or break to flat-pack.
- Packs into: normal bike trailer (tubes + euroboxes for connectors); panels via panel bike trailer.
- Store dry. Check pins aren't bent before repacking.
7. Compatible add-ons
What this hub accepts:
8. Media & credits
- Photos - Drawings - Exploded diagram
- Linked: Connector (the core joint)
Designed by . - Year . - Iteration . - Last updated: .
mobil/assemblies/structures/hub_garage.txt · Last modified: by 127.0.0.1